Pular para o conteúdo principal
Exclusive System · Stainless Steel

Stainless Steel Roof Lifeline

Fixed over the sheets, without piercing the roof

A spider-type system, entirely in stainless steel, fixed over trapezoidal, standing-seam, galvanized or kalhetão roof sheets. The roof's watertightness is preserved and the risk of future leaks is eliminated.

NR-35 compliance project with integrated energy absorber and tension indicator, validated through testing at Anchor's own laboratory.

Stainless

steel throughout

Zero

through-drilling

Absorber

integrated energy absorber

NR-35

documented design

Spider-type stainless steel lifeline installed over a trapezoidal metal roof
Compliance and validation:NR-35In-house lab testingEnergy absorberTension indicator

Protecting whoever climbs the roof without compromising it

Roof maintenance, gutter cleaning, exhaust inspection and solar panel installation put workers on fragile, sloped surfaces without anchor points. Improvised solutions create a second liability: systems that pierce the sheet compromise watertightness and generate leaks, corrosion and warranty disputes with the roof manufacturer.

Without an engineering solution, the manager trades one risk for another: protect the worker by drilling the roof, or preserve the roof by leaving the worker unprotected.

Risk of fatal fall

A fragile, sloped surface without engineered anchorage is the classic scenario of a fall with fatal consequences in roof work.

Regulatory and labor risk

NR-35 requires a dimensioned, documented fall protection system for any work above 2 meters. Roof access without engineered anchorage exposes the company to fines, work embargoes and liability in case of an accident.

Asset risk

Drilling the roof to install anchors transfers the safety problem to the asset's integrity. Every hole is a potential leak point for decades to come.

A spider-type lifeline fixed over the sheets

Anchor designs and installs roof lifelines fixed over the sheets, with no need to pierce them and no access required from under the roof, which simplifies installation and eliminates interference with the operation below.

All-stainless-steel construction

Spider fixing plates, cables and components in stainless steel, with corrosion resistance matching the roof's service life, even in aggressive industrial environments.

Watertightness preserved by design

The spider geometry distributes loads over the sheet without through-drilling. The roof keeps its sealing function intact and the system prevents future leaks.

Energy absorber and tension indicator

The absorber limits the loads transmitted to the structure and the user in case of a fall. The tension indicator allows visual verification of cable pre-tensioning during periodic inspections.

Tested in our own laboratory

Before reaching your roof, the solution is tested at Anchor's own laboratory. Anchor is the only company in Brazil that field-tests every solution it uses.

Spider-type lifeline installed over a trapezoidal metal roof
System installed over trapezoidal sheeting
Spring energy absorber and stainless steel spider plate on the roof sheet
Energy absorber integrated into the system
Tensioned stainless steel lifeline cable over a standing-seam roof
Standing-seam fixing, no through-drilling
Stainless steel spider fixing plate mounted on a metal roof sheet
Spider plate: loads distributed over the sheet

Engineering differentials

What sets the system apart, verifiable in design and in the field.

  • Fixing over the sheet, with no through-drilling: roof watertightness preserved by design
  • Installation without access from under the roof, with no interference in plant operations
  • 100% stainless steel construction, corrosion resistant in industrial environments
  • Energy absorber and tension indicator integrated into the system
  • Validation testing in our own laboratory, with practical and chemical tests
  • Compatible with multiple sheet profiles: trapezoidal, standing-seam, galvanized and kalhetão
  • Design, manufacturing, installation and maintenance by the same supplier, turn-key, born from the MG Cinto group
  • Multidisciplinary engineering team and service across the entire Brazilian territory

Specifications and applications

System parameters, in the specification your project will require.

ParameterAnchor specification
System typeFlexible roof lifeline with spider-type fixing
MaterialStainless steel (entire system)
Fixing methodOver the sheets, no through-drilling, no under-roof access
Compatible sheet profilesTrapezoidal, standing-seam, galvanized, kalhetão
Integrated devicesEnergy absorber and tension indicator
ValidationPractical and chemical testing in our own laboratory
Reference standardNR-35, Work at Height (Brazil)
Typical applicationsRoof maintenance, gutter cleaning, rooftop equipment inspection, solar panel installation and maintenance
Supply modelTurn-key: field survey, design, manufacturing, installation and maintenance
CoverageThe entire Brazilian territory

Frequently asked questions

Does installation require drilling or piercing the roof sheets?

No. The spider-type system is fixed over the sheets, with no through-drilling, preserving the roof's watertightness. Installation also requires no access from under the roof, avoiding interference with plant operations.

Does the system work on any sheet type?

The solution was developed for trapezoidal and standing-seam sheets, and is also applied to galvanized and kalhetão profiles. Anchor's field survey evaluates the profile, condition and supporting structure of your roof before defining the project configuration.

How do I know the system will withstand a real fall?

The solution is tested at Anchor's own laboratory and incorporates an energy absorber that limits the loads transmitted to the structure and the user. The integrated tension indicator allows visual verification of the system's condition during periodic inspections.

Who performs the periodic inspection after installation?

Anchor itself. Our engineering team performs inspection and validation of lifeline systems across the entire Brazilian territory, including existing systems installed by third parties.

Request a study for your roof

Send the plant location, sheet type and the activities performed on the roof. Our engineering team carries out the field survey and delivers the NR-35 compliance design with the lifeline configuration suited to your roof, without compromising watertightness.